Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 8 de 8
Filter
1.
Coluna/Columna ; 22(4): e273482, 2023. tab, graf, il
Article in English | LILACS | ID: biblio-1528458

ABSTRACT

ABSTRACT: Objective: Evaluate the inter and intra-observer reliability of Nash and Moe's grades, used to assess patients diagnosed with Adolescent Idiopathic Scoliosis (AIS). Methodology: Forty-seven representative x-rays of patients with AIS were randomly selected to evaluate the apical vertebral rotation (AVR) using Nash and Moe's grades. The evaluation of the AVR was made independently in two distinct moments by two observers. The inclusion criteria in the study were a patient diagnosed with AIS and an orthostasis radiography with a good-quality image. An agreement study between the evaluations and the inter and intraobserver's reliability was determined using Kappa's statistics with a confidence interval of 95%. Results: The interobservers' Kappa's value in the first evaluation was 0,44 (CI 95%; 0,22-0,66) and 0,37 (CI 95%; 0,17-0,56) in the second. In the intraobservers' evaluations, the Kappa's value for examiner 1 was 0,61 (CI 95%; 0,40-0,81) and 0,46 (CI 95%; 0,22-0,70) for examiner 2. Conclusion: This study's results demonstrated that Nash and Moe's grades are unreliable for evaluating vertebral rotation in patients with AIS. Level of Evidence III; A Cross-Sectional Study.


RESUMO: Objetivo: Avaliar a confiabilidade inter e intraobservador da classificação de Nash & Moe, usada em pacientes diagnosticados com escoliose idiopática do adolescente (EIA). Metodologia: Quarenta e sete radiografias representativas de pacientes com EIA foram selecionadas aleatoriamente para avaliação da rotação da vértebra apical (RVA), usando a classificação de Nash & Moe. A avaliação do RVA foi realizada de forma independente em dois momentos distintos, por dois examinadores. Os critérios de inclusão no estudo foram: paciente com diagnóstico de EIA e radiografia realizada em ortostase, com imagem de boa qualidade. Foi realizado um estudo de concordância entre as avaliações, e a confiabilidade inter e intraobservador foi calculada utilizando a estatística de Kappa com intervalo de confiança (IC) de 95%. Resultados: O valor de Kappa interobservador na primeira avaliação foi de 0,44 (IC 95% de 0,22-0,66) e na segunda de 0,37 (IC 95% de 0,17 -0,56). Nas avaliações intraobservadores, o valor de Kappa para o examinador 1 foi de 0,61 (IC 95% de 0,40-0,81) e para o examinador 2 foi de 0,46 (IC 95% de 0,22-0,70). Conclusão: Os resultados deste estudo demonstraram que a classificação de Nash & Moe apresenta baixa confiabilidade na avaliação do grau de rotação vertebral em pacientes com EIA. Nível de Evidência III; Estudo Transversal.


RESUMEN: Objetivo: Evaluar la confiabilidad inter e intraobservador para la clasificación de Nash & Moe, usada para estudiar pacientes diagnosticados con Escoliosis Idiopática del Adolescente (EIA). Metodología: Cuarenta y siete radiografías representativas de pacientes con EIA fueron seleccionadas aleatoriamente para evaluación de la rotación de la vértebra apical (RVA) usando la clasificación de Nash & Moe. La evaluación fue hecha de modo independiente en dos momentos distintos, por dos evaluadores. Los criterios de inclusión en el estudio fueron: paciente con diagnóstico de EIA y radiografía realizada en ortostasis, con buena calidad de imagen. Se realizó un estudio de concordancia entre las evaluaciones y se calculó la fiabilidad interobservador e intraobservador mediante la estadística de Kappa con un intervalo de confianza (IC) del 95%. Resultados: El valor Kappa interobservador en la primera evaluación fue de 0,44 (IC 95%: 0,22-0,66) y en la segunda de 0,37 (IC 95%: 0,17 -0,56). En las evaluaciones intraobservador, el valor Kappa para el examinador 1 fue de 0,61 (IC 95%: 0,40-0,81) y para el examinador 2 fue de 0,46 (IC 95%: 0,22-0,70). Conclusión: Los resultados de este estudio demostraron que la clasificación de Nash & Moe tiene una baja fiabilidad para evaluar el grado de rotación vertebral en pacientes con EIA. Nivel de Evidencia III; Estudio Transversal.


Subject(s)
Humans , Adolescent , Spine , Spinal Curvatures , Radiography, Panoramic
2.
Coluna/Columna ; 22(3): e273483, 2023. tab, graf
Article in English | LILACS | ID: biblio-1520795

ABSTRACT

ABSTRACT: Objective: To evaluate the axial correction capacity of the 3D brace in treating Adolescent Idiopathic Scoliosis (AIS). Methods: A retrospective study was carried out with 61 patients with AIS who obtained the 3D brace, between 2019 and 2022, in a laboratory that manufactures orthotics and orthopedic prostheses. These individuals underwent independent analysis of radiographic parameters by evaluating vertebral rotation using the Nash and Moe classification. The analyzed radiographs were taken in orthostasis before and after treatment with the 3D vest. Patients were divided into groups I and II-IV according to the Nash and Moe radiographic classification. Corrective capacity was estimated by assessing the degree of vertebral rotation before and after treatment. Results: Of the 61 patients evaluated, 36 (59%) had Nash and Moe grade I, and 25 patients grade II-IV before treatment. After treatment, 13 (21%) had grade II-IV, and 48 had grade I. Of the patients categorized as II-IV, 64% had improvement in the rotational profile. None clinical studies or radiographic parameter was associated with a change in rotational profile other than brace use (p=0.012). Conclusion: In the studied sample, treatment with the 3D vest promoted a change in vertebral rotation according to the Nash and Moe classification. The majority showed improvement in this parameter of evaluation of treatment of AIS. Level of Evidence III; Retrospective Study.


RESUMO: Objetivo: Avaliar a capacidade de correção axial do colete 3D no tratamento da Escoliose Idiopática do Adolescente (EIA). Métodos: Realizou-se estudo retrospectivo com 61 pacientes com EIA que obtiveram o colete 3D, entre 2019 e 2022, em um laboratório de confecção de órteses e próteses ortopédicas. Esses indivíduos foram submetidos à análise independente dos parâmetros radiográficos através da avaliação da rotação vertebral pela classificação de Nash e Moe. As radiografias analisadas foram realizadas em ortostase antes e após o tratamento com o colete 3D. Os pacientes foram separados em grupo I e grupo II-IV de acordo com a classificação radiográfica de Nash e Moe. A capacidade de correção foi estimada pela avaliação do grau de rotação vertebral antes e depois do tratamento. Resultados: Dentre os 61 pacientes avaliados, 36 (59%) apresentavam grau I, e 25 pacientes grau II-IV de Nash e Moe, antes do tratamento. Após o tratamento, 13 (21%) apresentavam grau II-IV e, 48 pacientes apresentavam grau I. Dos pacientes categorizados como II-IV, 64% tiveram melhora no perfil rotacional. Nenhum parâmetro clínico ou radiográfico estudado esteve associado com a mudança no perfil rotacional além do uso do colete (p=0,012). Conclusões: Na amostra estudada, o tratamento com o colete 3D promoveu mudança na rotação vertebral pela classificação de Nash e Moe. A maioria dos pacientes apresentou melhora neste parâmetro de avaliação de tratamento da EIA. Nível de Evidência III; Estudo Retrospectivo.


RESUMEN: Objetivo: Evaluar la capacidad de corrección axial del corsé 3D en el tratamiento de la Escoliosis Idiopática del Adolescente (EIA). Métodos: Se realizó un estudio retrospectivo con 61 pacientes con EIA que obtuvieron el corsé 3D, entre 2019 y 2022, en un laboratorio que fabrica ortesis y prótesis ortopédicas. Estos individuos se sometieron a un análisis independiente de los parámetros radiográficos a través de la evaluación de la rotación vertebral utilizando la clasificación de Nash y Moe. Las radiografías analizadas se tomaron en ortostasis antes y después del tratamiento con el corsé 3D. Los pacientes se dividieron en grupo I y grupo II-IV según la clasificación radiográfica de Nash y Moe. La capacidad correctora se estimó evaluando el grado de rotación vertebral antes y después del tratamiento. Resultados: De los 61 pacientes evaluados, 36 pacientes (59%) tenían grado I de Nash y Moe, y 25 grado II-IV antes del tratamiento. Después del tratamiento, 13 (21%) tenían grado II-IV, y 48 grado I. De los pacientes categorizados como II-IV, el 64% tuvo mejoría en el perfil rotacional. Ningún parámetro clínico o radiográfico estudiado se asoció con el cambio en el perfil de rotación que no sea el uso de aparatos ortopédicos (p = 0,012). Conclusiones: En la muestra estudiada, el tratamiento con el corsé 3D promovió un cambio en la rotación vertebral según la clasificación de Nash y Moe. La mayoría mostró mejoría en este parámetro de evaluación del tratamiento de la EIA. Nivel de Evidencia III; Estudio Retrospectivo.


Subject(s)
Humans , Adolescent , Orthopedics , Analysis of Variance , Conservative Treatment
3.
Coluna/Columna ; 21(1): e250506, 2022. tab, graf
Article in English | LILACS | ID: biblio-1364776

ABSTRACT

ABSTRACT Introduction: This study aims to evaluate the safety of using the cortical path screw with transfixation of the second cortical bone in relation to the vascular structures. Methods: This retrospective observational study (level of evidence: III, study of non-consecutive patients) analyzed data from the medical records of patients who underwent computed angiotomography scans of the abdomen at Hospital Mater Dei, measuring, in millimeters, the distance between the point of the lumbar vertebra considered the anatomical reference for the transfixation of the second cortical bone and the vascular structures adjacent to the spine (abdominal aorta, inferior vena cava, iliac vessels, segmental lumbar arteries). Results: Forty-eight patients were evaluated, with a mean age of 60 years (±8 years, 41-75), of whom 52% were male and 48% female. The measurements obtained between the pre-vertebral vessels and the possible screw exit points did not demonstrate contact in any of the vertebrae studied. Conclusions: The measurements obtained suggest the safety of using the cortical path screw transfixing the second cortical bone. Knowing the position of the vessels is essential to reduce intra- and postoperative complications related to spinal instrumentation. Level of evidence III; Study of non-consecutive patients.


RESUMO Introdução: Este trabalho objetiva avaliar a segurança do uso do parafuso de trajeto cortical com transfixação da segunda cortical óssea com relação às estruturas vasculares. Métodos: Estudo observacional retrospectivo (nível de evidência: III, estudo de pacientes não consecutivos) analisou dados de prontuários de pacientes submetidos ao exame de angiotomografia computadorizada do abdome no Hospital Mater Dei, realizando a medida, em milímetros, entre o ponto da vértebra lombar considerado a referência anatômica para a transfixação da segunda cortical óssea e as estruturas vasculares adjacentes à coluna (aorta abdominal, veia cava inferior, vasos ilíacos, artérias lombares segmentares). Resultados: Foram avaliados 48 pacientes, com média de idade de 60 anos (±8 anos, 41-75), sendo 52% do sexo masculino e 48% do feminino. As medidas obtidas entre os vasos pré-vertebrais e os pontos possíveis de saída do parafuso não demonstraram contato, em todas as vértebras estudadas. Conclusões: As medidas obtidas sugerem a segurança do uso do parafuso de trajeto cortical transfixando a segunda cortical óssea. Conhecer a posição dos vasos é essencial para reduzir as complicações intra e pós-operatórias relacionadas à instrumentação da coluna vertebral. Nível de evidência III; Estudo de pacientes não consecutivos.


RESUMEN Introducción: Este estudio tiene como objetivo evaluar la seguridad del uso del tornillo de trayectoria cortical con transfijación de la segunda cortical ósea con respecto a las estructuras vasculares. Métodos: Estudio observacional retrospectivo (nivel de evidencia: III, estudio de pacientes no consecutivos) que analizó datos de registros médicos de pacientes sometidos a examen de angiografía por tomografía computarizada de abdomen en el Hospital Mater Dei, realizando la medición, en milímetros, entre el punto de la vértebra lumbar considerado la referencia anatómica para la transfijación de la segunda cortical ósea y las estructuras vasculares adyacentes a la columna (aorta abdominal, vena cava inferior, vasos ilíacos, arterias lumbares segmentarias). Resultados: Se evaluaron 48 pacientes, con una edad promedio de 60 años (±8 años, 41-75); 52% eran hombres y 48% mujeres. Las medidas obtenidas entre los vasos prevertebrales y los posibles puntos de salida del tornillo no demostraron contacto en todas las vértebras estudiadas. Conclusiones: Las medidas obtenidas sugieren la seguridad de utilizar el tornillo de trayectoria cortical transfijando la segunda cortical ósea. Conocer la posición de los vasos es fundamental para reducir las complicaciones intra y postoperatorias relacionadas con la instrumentación espinal. Nivel de evidencia III; Estudio de pacientes no consecutivos.


Subject(s)
Humans , Male , Female , Middle Aged , Spinal Fusion , Orthopedic Procedures , Blood Circulation
4.
Coluna/Columna ; 20(3): 174-180, July-Sept. 2021. tab, graf
Article in English | LILACS | ID: biblio-1339749

ABSTRACT

ABSTRACT Objective To evaluate the immediate correction capacity of the Wood-Chêneau-Rigo brace (WCR), produced using digital technological resources and robotic engineering, in primary and secondary curves of adolescent idiopathic scoliosis (AIS). Methods A retrospective study was conducted of 138 patients with a diagnosis of AIS and who received a WCR brace from a laboratory that makes orthoses and orthopedic prostheses between 2019 and 2021. These individuals were submitted to an independent analysis of the radiographic parameters by a single researcher, the main outcome of which was the standardized measurement of the main and secondary curves using the Cobb method. The radiographs analyzed were performed in orthostasis before and immediately after the adaptation of the brace on the patient. The correction capacity was calculated as the ratio of the difference between the pre- and post-brace curves to the pre-brace curve. Results The mean correction with the WCR was 48.4% for the main curve and 41.0% for the secondary curve. The level of correction of the main curve was significantly higher in patients with a main curve with the apex of convexity in the thoracolumbar region (p = 0.004), especially in the left thoracolumbar region (p = 0.010); curves of magnitude between 10º and 24.9º (p <0.001); and curves classified as simple (p <0.001). Conclusion The use of the WCR, which is produced using modern technological resources, was effective in the immediate correction of AIS. Long-term studies on this new modality of conservative scoliosis treatment are necessary. Level of evidence III; Retrospective study.


RESUMO Objetivo Avaliar a capacidade de correção imediata do colete Wood-Chêneau-Rigo (WCR), produzido com recursos tecnológicos digitais e de engenharia robótica, em curvas primárias e secundárias de escoliose idiopática do adolescente (EIA). Métodos Realizou-se um estudo retrospectivo com 138 pacientes com diagnóstico de EIA que adquiriram o colete WCR entre 2019 e 2021 em um laboratório de produção de órteses e próteses ortopédicas. Esses indivíduos foram submetidos à análise independente dos parâmetros radiográficos por um único pesquisador, tendo como desfecho principal a medida padronizada das curvas principal e secundária pelo método de Cobb. As radiografias analisadas foram realizadas em ortostase antes e imediatamente depois da adaptação do colete no paciente. A capacidade de correção foi calculada pela razão entre a diferença das curvas pré e pós-colete e a curva pré-colete. Resultados A média de correção da curva primária com o WCR foi de 48,4% e a da curva secundária foi de 41,0%. O nível de correção da curva primária foi significativamente maior nos pacientes com curva principal com ápice da convexidade na região toracolombar (p = 0,004), principalmente toracolombar à esquerda (p = 0,010); curvas com magnitude entre 10º e 24,9º (p < 0,001) e curvas do tipo simples (p < 0,001). Conclusões O colete WCR, produzido com modernos recursos tecnológicos, foi eficaz na correção imediata da EIA. São necessários estudos a longo prazo sobre essa nova modalidade de tratamento conservador da escoliose. Nível de Evidência III; Estudo retrospectivo.


RESUMEN Objetivo Evaluar la capacidad de corrección inmediata del corsé de Wood-Chêneau-Rigo (WCR), producido con recursos tecnológicos digitales e ingeniería robótica, en curvas primarias y secundarias de la escoliosis idiopática del adolescente (EIA). Métodos Se realizó un estudio retrospectivo de 138 pacientes con diagnóstico de EIA que adquirieron el corsé WCR entre 2019 y 2021 en un laboratorio de producción de ortesis y prótesis ortopédicas. Estos individuos fueron sometidos a un análisis independiente de los parámetros radiográficos por un solo investigador, siendo el resultado principal la medición estandarizada de las curvas principal y secundaria por el método de Cobb. Las radiografías analizadas se tomaron en bipedestación antes e inmediatamente después de la adaptación del corsé al paciente. La capacidad de corrección se calculó por la razón entre la diferencia entre las curvas de antes y de después del uso del corsé y la curva de antes del corsé. Resultados La corrección promedio de la curva primaria con el WCR fue del 48,4% y de la curva secundaria fue del 41,0%. El nivel de corrección de la curva primaria fue significativamente más grande en pacientes con una curva principal con vértice de la convexidad en la región toracolumbar (p = 0,004), principalmente toracolumbar a la izquierda (p = 0,010); curvas con magnitud entre 10º y 24,9º (p < 0,001) y curvas simples (p < 0,001). Conclusiones El uso corsé WCR, producido con modernos recursos tecnológicos, fue efectivo en la corrección inmediata de la EIA. Se necesitan estudios a largo plazo sobre esta nueva modalidad de tratamiento conservador de la escoliosis. Nivel de evidencia III; Estudio retrospectivo.


Subject(s)
Humans , Male , Female , Child , Adolescent , Orthotic Devices , Scoliosis/rehabilitation , Printing, Three-Dimensional , Retrospective Studies , Analysis of Variance , Conservative Treatment
5.
Coluna/Columna ; 19(2): 127-132, Apr.-June 2020. tab, graf
Article in English | LILACS | ID: biblio-1133557

ABSTRACT

ABSTRACT Objective Morphometric study of the positioning of the cortical trajectory pedicle screw in the lumbar spine of Brazilian patients of different sexes and ages, through the use of computed tomography images, in order to obtain more reliable data about cortical screw insertion and the variations observed, providing assistance for a safer, more effective approach with fewer complications. Methods Selection of 100 patients from a database, alternating by sex, measuring the length, diameter, cephalic angulation, and lateral angulation of the vertebrae from L1 to L5. Results Statistically significant measurements were obtained for the four different parameters in relation to sex. The mean age was 56, with a minimum of 20 and a maximum of 87 years. The L4 and L5 screws showed a reduction in relation to the other levels, while the width showed a progressive increase starting at L3. Lateral angulation was the parameter with the least variation among the levels, while there was greater variation and a reduction from L4 to L5 in cephalic angulation. Conclusion Statistically significant results were obtained for length, diameter, lateral and cephalic angulation. Sex was a significant factor in spine surgery instrumentation using the cortical trajectory pedicle screw technique. Level of evidence I; Diagnostic study (investigation of an examination for diagnosis).


RESUMO Objetivo Estudo morfométrico do posicionamento de parafuso pedicular com trajeto cortical na coluna lombar de pacientes brasileiros de diferentes sexos e idades, por meio da utilização de imagens de tomografia computadorizada, com o intuito de se obter dados mais fidedignos em relação à inserção do parafuso cortical e às variações observadas, proporcionando assim subsídios para uma abordagem mais segura, eficaz e com menos complicações. Métodos Seleção de 100 pacientes em bases de dados, com alternância de sexo, auferindo o comprimento, diâmetro, angulação cefálica e angulação lateral das vértebras de L1 à L5. Resultados Foram obtidas medições com significância estatística em relação ao sexo nos quatro diferentes parâmetros mensurados. A média de idade foi de 56 anos, com mínima de 20 e máxima de 87 anos. Os parafusos de L4 e L5 mostraram redução em relação aos outros níveis, enquanto a largura se mostrou progressiva a partir de L3. A angulação lateral foi o parâmetro que apresentou a menor variância entre eles, ao contrário da angulação cefálica com maior variação e diminuição de L4 e L5. Conclusões Foram obtidos resultados de comprimento, largura, angulação lateral e cefálica estatisticamente significativos. O sexo apresentou-se como fator significativo na instrumentação da cirurgia da coluna pela técnica do parafuso pedicular de trajeto cortical. Nível de evidência I; Estudo diagnóstico (investigação de um exame para diagnóstico).


RESUMEN Objetivo Estudio morfométrico del posicionamiento de tornillo pedicular con trayecto cortical en la columna lumbar de pacientes brasileños de diferentes sexos y edades, mediante el uso de imágenes de tomografía computarizada, con el objetivo de obtener datos más fidedignos con relación a la inserción del tornillo cortical y a las variaciones observadas, proporcionando así subsidios para un abordaje más seguro, eficaz y con menos complicaciones. Métodos Selección de 100 pacientes en bases de datos, con alternancia de sexo, midiendo la longitud, diámetro, angulación cefálica y angulación lateral de las vértebras desde L1 hacia L5. Resultados Fueron obtenidas medidas con significancia estadística con relación al sexo en los cuatro diferentes parámetros medidos. El promedio de edad fue de 56 años, con edad mínima de 20 y máxima de 87 años. Los tornillos de L4 y L5 mostraron reducción con relación a los otros niveles, mientras que el ancho se mostró progresivo a partir de L3. La angulación lateral fue el parámetro que presentó la menor variancia entre ellos, al contrario de la angulación cefálica, con mayor variación y disminución de L4 y L5. Conclusiones Fueron obtenidos parámetros de longitud, ancho, angulación lateral y cefálica estadísticamente significativos. El sexo se presentó como factor en la instrumentación de la cirugía de la columna por la técnica del tornillo pedicular de trayecto cortical. Nivel de evidencia I; Estudio Diagnóstico (investigación de un examen para diagnóstico).


Subject(s)
Humans , Spine/surgery , Spinal Fusion , Bone Screws
6.
Coluna/Columna ; 18(3): 214-216, July-Sept. 2019.
Article in English | LILACS | ID: biblio-1019774

ABSTRACT

ABSTRACT Objective The objective of this study was to determine the prevalence of patients with colonization of methicillin-resistant Staphylococcus aureus (MRSA) in the nasal mucosa, who underwent elective spinal procedures. Methods Retrospective study of the medical records of all patients submitted to elective procedures, totaling 125 individuals in the period of 2015 and 2017, performed by two spinal surgeons of the Orthopedics and Traumatology Service of Hospital Mater Dei, Belo Horizonte, Minas Gerais. The pre-operative investigation of MRSA consisted of the collection of a nasal swab for microbiological culture. Results Of the 125 patients evaluated, three (2.4%) showed positive results for MRSA nasal colonization. This prevalence is consistent with the international literature, that ranges from 1.5 to 5.9%. Of these patients none had infection of the surgical wound, probably due to the preoperative prophylactic measures. Conclusions Despite the limitations of the study, we found that the prevalence of carriers of this nasal MRSA population is similar to that of populations worldwide . Level of evidence III; Retrospective Study.


RESUMO Objetivo O objetivo desse trabalho foi determinar a prevalência dos pacientes submetidos a procedimentos eletivos de coluna com mucosa nasal colonizada por Staphylococcus aureus Meticilina Resistente (MRSA). Métodos Foi realizado estudo retrospectivo dos prontuários de todos os pacientes submetidos a procedimentos eletivos, totalizando 125, entre 2015 e 2017, por dois cirurgiões de coluna do serviço de Ortopedia e Traumatologia do Hospital Mater Dei, de Belo Horizonte, Minas Gerais. A investigação pré-operatória para MRSA consistiu em swab nasal submetido à cultura microbiológica. Resultados Dos 125 pacientes avaliados, três (2,4%) apresentaram resultado positivo para colonização nasal por MRSA. Essa prevalência está de acordo com a literatura estrangeira, que varia de 1,5 a 5,9%. Desses pacientes, nenhum apresentou infecção da ferida operatória, provavelmente devido às medidas de profilaxia instituídas. Conclusão Apesar das limitações do estudo, constatamos que a população estudada apresenta prevalência de carreamento nasal de MRSA similar às populações estrangeiras. Nível de evidência III; Estudo Retrospectivo.


RESUMEN El objetivo de este estudio fue determinar la prevalencia de pacientes con colonización de Staphylococcus aureus resistente a la meticilina (SARM) en la mucosa nasal que se sometieron a procedimientos electivos de columna vertebral. Métodos Estudio retrospectivo de los registros médicos de todos los pacientes sometidos a procedimientos electivos, con un total de 125 individuos en el período de 2015 a 2017, realizado por dos cirujanos de columna vertebral del Servicio de Ortopedia y Traumatología del Hospital Mater Dei, de Belo Horizonte, Minas Gerais. La investigación preoperatoria de SARM consistió en la recolección de un hisopo nasal para cultivo microbiológico. Resultados De los 125 pacientes evaluados, tres (2,4%) tuvieron resultados positivos para la colonización nasal por SARM. Esta prevalencia está de acuerdo con la literatura internacional, que varía de 1,5% a 5,9%. De estos pacientes, ninguno tuvo infección de la herida quirúrgica, probablemente debido a las medidas profilácticas preoperatorias. Conclusiones A pesar de las limitaciones del estudio, encontramos que la prevalencia de portadores de SARM nasal de esta población es similar a la de poblaciones de todo el mundo. Nivel de Evidencia III; Estudio retrospectivo.


Subject(s)
Humans , Spine , Staphylococcus aureus , Prevalence
7.
Coluna/Columna ; 9(3): 265-270, jul.-set. 2010. ilus, graf, tab
Article in Portuguese | LILACS | ID: lil-570578

ABSTRACT

OBJETIVO: Comparar a rigidez de um sistema de fixação pedicular composto por parafusos pediculares poliaxiais de travamento tipo Dytech® com outro composto por parafusos pediculares poliaxiais com travamento do tipo Lock 1®, submetidos a forças de compressão. MÉTODOS: A amostra utilizada para avaliar os sistemas de fixação respeitou as regras do padrão formulado pela American Society for Testing Materials (ASTM) no ensaio F1717-04. Os modelos foram divididos em: Grupo 1, composto pelos ensaios de parafusos poliaxiais com sistema Dytech® de travamento, e o Grupo 2, formado por parafusos poliaxiais com travamento tipo Lock 1®. Foram testados três conjuntos completos montados. Cada sistema foi testado uma única vez por ser esse um ensaio destrutivo. O instrumental implantado foi produzido com titânio de mesma origem. Os grupos experimentais foram submetidos a testes mecânicos na máquina universal de ensaios EMIC, modelo EMIC DL 10000®. RESULTADOS: Os resultados de compressão nas amostras do Grupo 1 tiveram uma carga máxima média de 967,17 N e carga de escoamento média de 804,71 N. Nas amostras do Grupo 2 tivemos uma carga máxima média de 906,04 N e carga de escoamento média de 834,56 N. A respeito da integridade dos instrumentais metálicos usados, não foi observado nenhum tipo de escorregamento ou soltura de porcas, parafusos ou outros componentes. CONCLUSÃO: O sistema de parafusos poliaxiais com travamento tipo Dytech® apresentou valores de rigidez maiores, enquanto o sistema de parafusos com travamento tipo Lock 1® mostrou deslocamento máximo maior.


OBJECTIVE: To compare rigidity of a pedicle fixation system composed of poliaxial pedicle screws with Dytech® lock system to one composed of poliaxial screws with Lock 1® system, submitted to compression strengths. METHODS: The sample used to evaluate the fixation systems respected the norms of the standard described by the American Society for Testing Materials (ASTM) in trial F1717-04. The models were divided into: Group 1, composed of trials using poliaxial screws with Dytech® system, and Group 2, used poliaxial screws with Lock 1® system. Three complete sets were tested. Each system was tested only once because itïs a destructive essay. The implanted components were produced with titanium coming from the same origin. The experimental groups were submitted to mechanical tests in a universal testing machine EMIC, model EMIC DL 10000®. RESULTS: The samples of Group 1 showed an average maximum charge of 967,17 N, and an average discharging load of 814,71 N. The samples of Group 2 showed an average maximum charge of 906,04 N, and an average discharging load of 834,56 N. About the integrity of the used metallic components, was not noted any kind of failure in all of them. CONCLUSION: The pofilaxial screws system with Dytech® lock has presented greater rigidity, while the Lock 1® system screws showed greater maximum displacement.


OBJETIVO: comparar la rigidez de un sistema de fijación pedicular compuesto por tornillos pediculares poliaxiales de traba tipo Dytech® con otro compuesto por tornillos pediculares poliaxiales con traba del tipo Lock 1®, sometidos a fuerzas de compresión. MÉTODOS: la muestra utilizada para evaluar los sistemas de fijación respetó las reglas del patrón formulado por la American Society for Testing Materials (ASTM) en el ensayo F1717-04. Los modelos fueron divididos en: Grupo 1, compuesto por los ensayos de tornillos poliaxiales con sistema Dytech® de traba, y el Grupo 2, formado por tornillos poliaxiales con traba tipo Lock 1®. Fueron probados tres conjuntos completos montados. Cada sistema fue probado una vez por ser ese un ensayo destructivo. El instrumental implantado fue producido con titanio del mismo origen. Los grupos experimentales fueron sometidos a pruebas mecánicas en la máquina universal de ensayos EMIC, modelo EMIC DL 10000®. RESULTADOS: los resultados de compresión en las muestras del Grupo 1 tuvieron una carga máxima promedio de 967.17 N y carga de declive promedio de 804.71 N. En las muestras del Grupo 2, tuvimos una carga máxima promedio de 906.04 N y carga de declive promedio de 834.56 N. Con respecto a la integridad de los instrumentales metálicos usados, no fue observado ningún tipo de deslizamiento o soltura de tuercas, tornillos y otros componentes. CONCLUSIÓN: el sistema de tornillos poliaxiales con traba tipo Dytech® presentó valores de rigidez mayores, mientras que el sistema de tornillos con traba tipo Lock 1® mostró un desplazamiento mayor.


Subject(s)
Humans , Biomechanical Phenomena , Bone Plates , Bone Screws , Fracture Fixation , Titanium
8.
Coluna/Columna ; 9(2): 113-118, abr.-jun. 2010. ilus, tab
Article in Portuguese | LILACS | ID: lil-557018

ABSTRACT

OBJETIVO: comparar a rigidez de um sistema de instrumentação da coluna vertebral composto por parafusos pediculares fixos com duplo bloqueio (interno e externo) com um sistema composto por parafusos pediculares fixos com bloqueio interno único, submetidos a forças de compressão. MÉTODOS: o modelo experimental utilizado nesses testes para avaliação dos sistemas de fixação foi elaborado de acordo com as normas descritas pela American Society for Testing Materials (ASTM) no ensaio F1717-04. Foram montados dois grupos, sendo o Grupo 1 composto pelos ensaios com parafusos fixos com sistema de duplo bloqueio e o Grupo 2, com parafusos fixos com bloqueio interno único. Foram utilizados três conjuntos de hastes e parafusos para cada grupo. Cada conjunto foi submetido a um teste biomecânico. Os componentes metálicos utilizados foram todos produzidos pela mesma empresa, apresentando mesma origem em relação à matéria-prima. Os modelos experimentais foram submetidos a testes mecânicos na máquina universal de ensaios EMIC, modelo EMIC DL 10000. RESULTADOS: os resultados obtidos no ensaio de compressão nas amostras do Grupo 1 apresentaram uma carga máxima média de 2104,15 N e uma carga de escoamento média de 1882,55 N. Os resultados obtidos no ensaio de compressão nas amostras do Grupo 2 apresentaram uma carga máxima média de 1420,5 N e uma carga de escoamento média de 1314,37 N. CONCLUSÃO: o sistema de parafusos fixos com duplo bloqueio (Grupo 1) apresentou maior resistência a forças de compressão quando comparado ao sistema de parafusos com travamento interno isolado.


OBJECTIVE: to compare the rigidity of a pedicle fixation system composed of fixed pedicle screws with double locked system (internal and external) to one composed of fixed pedicle screws with single internal locked system, submitted to compression strengths. METHODS: the experimental model used to evaluate the fixation systems was constructed according to the standard described by the American Society for Testing Materials (ASTM) in trial F1717-04. The samples were divided into two groups. Group 1 was composed of tests with fixed screws with double locked system; in Group 2 fixed screws with single internal locked system were used. Three sets of rods and screws were used for each group; these sets were submitted to a biomechanical test. The metallic components were produced by the same company and with the same origin. The experimental groups were submitted to mechanical tests at the universal testing machine EMIC, model EMIC DL 10000. RESULTS: the results obtained in the compression trial in samples of Group 1 showed an average maximum charge of 2104,15 N and an average discharging load of 1882,55 N. The results obtained in the compression trial in the samples of Group 2 showed an average maximum charge of 1420,5 N and an average discharging load of 1314,37 N. CONCLUSION: the screws with double locked system (Group 1) presented greater resistance to compression strengths when compared to the screws with single internal locked system.


OBJETIVO: comparar la rigidez de un sistema de instrumentación de la columna vertebral, compuesto por tornillos pediculares fijos con duplo bloqueo (interno y externo), con un sistema compuesto por tornillos pediculares fijos con bloqueo interno único, sometidos a fuerzas de compresión. MÉTODOS: el modelo experimental utilizado en estos testes para evaluación de los sistemas de fijación fue elaborado de acuerdo con las normas descritas por la American Society for Testing Materials (ASTM) en el ensayo F1717-04. Fueron formados dos grupos, siendo el Grupo 1 compuesto por los ensayos con tornillos fijos con sistema de duplo bloqueo, y el Grupo 2, tornillos fijos con bloqueo interno único. Fueron utilizados tres conjuntos de astas y tornillos para cada grupo. Cada conjunto fue sometido a un test biomecánico. Los componentes metálicos utilizados fueron todos producidos por la misma empresa, con mismo origen en relación a la materia prima. Los modelos experimentales fueron sometidos a testes mecánicos en la máquina universal de ensayos EMIC, modelo EMIC DL 10000. RESULTADOS: los resultados obtenidos en el ensayo de compresión en las muestras del Grupo 1 tuvieron una carga máxima promedio de 2104.15 N y una carga de declive promedio de 1882.55 N. Los resultados obtenidos en el ensayo de compresión en las muestras del Grupo 2 tuvieron una carga máxima promedio de 1420.50 N y una carga de declive promedio de 1314.37 N. CONCLUSIÓN: el sistema de tornillos fijos con duplo bloqueo (Grupo 1) presentó mayor resistencia a las fuerzas de compresión cuando comparado a los tornillos con traba interna aislada.


Subject(s)
Bone Plates , Bone Screws , Fracture Fixation, Internal/instrumentation , Low Back Pain
SELECTION OF CITATIONS
SEARCH DETAIL